Description
The process is described for the buffer, see FEP Bu24
SKB Number
SKB FEP Number
TS17
Main Category
Main category for FEP
Internal process
System Component
System component to which the FEP applies
Top seal
Handling
Explanation of how the FEP is treated
Failed canister, Resaturation/ "thermal" period: Assumptions based on empirical data (no failures are expected this period).
Failed canister, Long-term after saturation and "thermal" period: Indirectly accounted for through the selection of parameters for radionuclide transport.
References
Bibliographic references to obtain more information
SR-Site Buffer, backfill and closure process report, TR-10-47, Section(s) 2.6.3, 7.5.1