Description
Canister surface temperatures are expected to be ~160 °C at a few years after emplacement, declining to ~80 °C after 1000 a. The temperature effects are considered in evaluating the corrosion allowance.
OPA Category
Category as used in the OPA assessment
SF/HLW canister
OPA Number
Number as used in the OPA assessment
2.01.1
Waste Relevance
Classes of waste to which this FEP is relevant
SF
NEA V1 IFEP Reference(s)
Related IFEPs from the NEA V1 IFEP list from 1999
2.1.11, 2.1.03