Description
The design criteria placed on the cast steel canister include a maximum acceptable dose at the canister surface for the operational period and the requirement that the canister should remain unbreached for at least 1000 years after repository closure. The canister design for HLW is the same as that considered in the Kristallin-I study.
OPA Category
Category as used in the OPA assessment
SF/HLW canister
OPA Number
Number as used in the OPA assessment
1.01
Waste Relevance
Classes of waste to which this FEP is relevant
HLW
NEA V1 IFEP Reference(s)
Related IFEPs from the NEA V1 IFEP list from 1999
1.1.07, 2.1.03