CSNI0078/01, included references:
- Description Of The Test Facility, MXA-1-101
- Instrumentation Equipment And Data Acquisition System, MXA-1-110
- Status Of The Instrumentation For Each Blowdown, MXA-1-111
- Structure Of The Data Tapes Containing Data Converted Into Physical Units,
MXA-1-112
- Conversion Of Data Into Physical Units, MXA-1-113
- Instrumentation Error Limits, MXA-1-114
- Evaluation System, Evaluation Methods And Error Limits For Gfk Measurements
In The Wetwell, MXA-1-115
- Blowdown 1 Results, MXA-1-201 ; - Blowdown 2 Results, MXA-1-202 ;
- Blowdown 3 Results, MXA-1-203 ; - Blowdown 4 Results, MXA-1-204 ;
- Blowdown 5 Results, MXA-1-205 ; - Blowdown 6 Results, MXA-1-206 ;
- Blowdown 7 Results, MXA-1-207 ; - Blowdown 8 Results, MXA-1-208 ;
- Blowdown 9 Results, MXA-1-209 ; - Blowdown 10 Results, MXA-1-210 ;
- Blowdown 11 Results, MXA-1-211 ; - Blowdown 12 Results, MXA-1-212 ;
- Blowdown 13 Results, MXA-1-213 ; - Blowdown 14 Results, MXA-1-214 ;
- Blowdown 15 Results, MXA-1-215 ; - Blowdown 16 Results, MXA-1-216
- Pressure Fluctuations In The Wetwell Pool (Steam Blowdowns)(Gfk), MXA-1-221
- Pressure Fluctuations In The Wetwell Pool (Water Blowdowns)(Gfk), MXA-1-222
- Vent Flow Measurements (Velocity, Composition Of The Vent Flow)(Gfk),
MXA-1-223
- Evaluation Methods, MXA-1-231
- Summary Report, MXA-1-301
- Description Of The Zoco II Containment Code, MXA-2-101
- Description Of The Zoco V Containment Code, MXA-2-102
- (Report Number Not Utilized, MXA-2-103)
- Description Of The PRESU Containment Code, MXA-2-104
- Description Of The CONTAC Containment Code, MXA-2-105
- Description Of The LOCACC Vessel Blowdown Code, MXA-2-106
- Calculations Carried Out With The Zoco II Code, MXA-2-201
- Calculations Carried Out With The Zoco V Code, MXA-2-202
- (Report Number Not Utilized, MXA-2-203)
- Calculations Carried Out With The PRESU Code, MXA-2-204
- Calculations Carried Out With The CONTAC Code, MXA-2-205
- Calculations Carried Out With The LOCACC Code, MXA-2-206
- Behaviour Of Iodine In The Containment During The Blowdown Runs. Experimental
Methods, MXA-3-101
- Leakage Of Xenon And Iodine From The Containment During The Blowdown Runs.
Experimental Methods, MXA-3-111
- Investigations Of The Stay Time Of Xenon In The Emergency Ventilation System,
MXA-3-112
- Containment Leakage Determined By The Absolute Method Before The Blowdown
Series, MXA-3-113
- Containment Leakage Determined By The Absolute Method After The Blowdown
Series, MXA-3-114
- Containment Leakage Determined By Radioactive Isotope Tracer Technique Before
And After The Blowdown Series, MXA-3-115
- Behaviour Of Iodine In The Containment During The Blowdown Runs. Results,
MXA-3-201
- Leakage Of Xenon And Iodine From The Containment During The Blowdown Runs.
Results, MXA-3-211
- The Application Of A Radioactive Tracer Isotope Method For Determining
Containment Leakage, MXA-3-212
- Behaviour Of Iodine In The Containment During The Blowdown Runs. Discussion
Of Results, MXA-3-301
- Leakage Of Xenon And Iodine From The Containment During The Blowdown Runs.
Discussion of Results, MXA-3-311
- Measuring Devices, MXA-4-201
- Automatic Switches, MXA-4-202
- Electrical Installation Materials, MXA-4-203
- Electric Motors, MXA-4-204
- Valve Actuators, MXA-4-205
- Paint And Heat Insulation, MXA-4-206
- Index To And Abstracts Of Final Reports, MXA-0-401
- Containment Response To A Loss Of Coolant Accident. Conclusions And
Recommendations, MXA-0-402
- Iodine And Xenon Experiments. Conclusions And Recommendations, MXA-0-403
- Component Tests. Conclusions And Recommendations, MXA-0-404
- Jan-Erik Marklund: Summary Report for ISP an International Standard Problem
for Containment Codes, Based on Blowdown No 18 in the Marviken Full Scale
Experiments, STUDSVIK/NR-84/464 (1984-09-19)