To submit a request, click below on the link of the version you wish to order.
Only liaison officers are authorised to submit online requests. Rules for requesters are
available here.
The Super Moby Dick experiment is devoted to study steady state critical flow in nozzles at medium to high pressure and for various thermal hydraulic conditions.
Three test sections are available. The test 12B305C corresponds to the "long nozzle test section".
It consists of a shaped or conical convergent nozzle 66.7 mm inlet diameter and 100 mm long, connected to a straight pipe 20.13 mm inner diameter and 363 mm long which is surmounted by a conical 7 deg. divergent section.
The mass flowrate for the test SMD 12R305C was not available. Data of the test 12B305C can be used, as it is very similar.
The experimental data provided correspond to pressure measurements.