4. DESCRIPTION OF TEST
Run 952 is a reference MSL break test
performed with a 100% break upstream of the main steam isolation
valve and with full ECCS actuation logic. The MSL break is
characterized by a system depressurization due to a break flow of
high mass quality, which is slower than with a recirculation line
break. Continuous flashing of the fluid in the pressure vessel was
observed. A slow decrease in the downcomer water level eventually
led to actuation of HPCS, but not LPCS or LPCI. About 2/3 of the
core was uncovered, but the coolant level recovered quickly
following HPCS injection. A peak cladding temperature of 752K was
reached.