Coolant:Water
Primary system volume:2.9 m3
Primary system pressure (max):17.2 MPa
Core flow area:0.043 m2
Scaling method:P-to-V(Kv)
Time scale:1
Volumetric scale:1/100
Height scale:1
Scaling approaches:
Number of loops:3
Number of single loops:3
HL inner diam.:118 mm
CL inner diam.:118 mm
Seal depth2.2 m
Number of FOR loops:1
Notes:
Preserv. Froude n
Number:3
Fluid:2-phase
Coastdown:Controlled
Number of sim. fuel Rods:428
Diameter:9.5 mm
Pitch:12.6 mm
Heated length:3.66 m
Max power:3 MW
Axial Peaking factor:1.6
Heating method:Indirect
Number:3
Type:U Tube
Num. tubes single loop:34
Pressure:8 MPa
ID:19.7 mm
OD:22 mm
Pitch:32.5 mm
BETHSY/9.1B, Cold Leg Break without HPSI and with delayed ultimate procedure, 1992
BETHSY/6.9C, Loss of residual heat removal system during mid-loop operation
BETHSY General description, SETh/LES/90-97/ April 1990