ENTRY            C0790   20010418
SUBENT        C0790001   20010418                                 
BIB                 13         40                                 
INSTITUTE  (1CANALA,1CANTMF,1USAORU,3SAFSAF)                      
             SAF = Univ. of Western Capetown, Bellville, S.Africa.
REFERENCE  (J,NP/A,424,549,1984)                                  
AUTHOR     (J.M.CAMERON,P.KITCHING,W.J.MCDONALD,J.PASOS,J.SOUKUP, 
           J.THEKKUMTHALA,R.ABEGG,D.A.HUTCHEON,C.A.MILLER,        
           A.W.STETZ,I.J.VAN HEERDEN)                             
TITLE      Cross sections and analyzing powers for the reaction   
            pd->3He+gamma at intermediate energies                
FACILITY   (MESON,1CANTMF)                                        
INC-SOURCE (POLIS)                                                
SAMPLE     Deuterated polyethylene targets wuth thicknesses of    
            75 - 130 mg/cm**2.                                    
METHOD     (EDE)                                                  
DETECTOR   (TELES,CEREN) Photons detected by cylinrical lead-     
            glass Cerenkov detectors, preceded by thin plastic    
            scintillator charged-particle veto counters.          
           (TELES,MWPC,SCIN) 3He recoil particles detected using  
            a telescope consisting of a wire counter, a thin      
            plastic DE counter, and a NaI or thick plastic        
            stopping or E counter.                                
           Beam intensity and polarization monitored using in-    
            beam polarimeter placed upstream of target.           
CORRECTION Corrected for:                                         
           . computer and electronic dead time,                   
           . proportional counter inefficiency,                   
           . pulse pile-up in E-counters,                         
           . losses of 3He particles which underwent nuclear      
             reactions in NaI detectors.                          
ERR-ANALYS (ERR-S) Statistical uncertainty given.                 
           Total scale uncertainty 8.6% and includes              
            contributions from:                                   
            . efficiency of 3He detectors (2%),                   
            . efficiency of Cerenkov detectors (4%),              
            . solid angle definition (2%),                        
            . beam-current determination (3%),                    
            . target thickness (5%),                              
            . target non-uniformity (4%).                         
STATUS     Data taken from Table I in reference.                  
           (APRVD) Approved by J.M. Cameron, 10 April 2001.       
HISTORY    (20010302C) VM                                         
ENDBIB              40          0                                 
NOCOMMON             0          0                                 
ENDSUBENT           43          0                                 