SUBENT        C0405003   19990205                                 
BIB                  4         11                                 
REACTION   (1-H-1(D,G)2-HE-3,,DA,,AV)                             
INC-SOURCE (POLIS,ATOMI) Polarized and unpolarized deuteron beams.
SAMPLE     Distilled H2O condensed every 6 hours on cooled (80 K) 
            Cu disc in Al target chanber.                         
ERR-ANALYS (ERR-T) Includes statistical and systematic            
            uncertainties added in quadrature.                    
           Systematic uncertainty includes errors in:             
           . beam current integration (1%),                       
           . efficiency measurement (6% at 5.5 MeV),              
           . stopping cross section curve (6%).                   
           (ERR-S) Statistical uncertainty                        
ENDBIB              11          0                                 
COMMON               3          3                                 
EN-MIN     EN-MAX     ERR-T      
KEV        KEV        PER-CENT   
 0.        80.         9.        
ENDCOMMON            3          0                                 
DATA                 3          7                                 
ANG        DATA       ERR-S      
ADEG       NB/SR      NB/SR      
  0.0       1.2590     0.0848    
 30.14      1.9083     0.0970    
 45.2       2.5809     0.1290    
 60.24      3.0411     0.1520    
 75.27      3.8048     0.1902    
 90.28      4.2584     0.2129    
180.0       1.01       0.05      
ENDDATA              9          0                                 
ENDSUBENT           29          0                                 