Request ID | 27 | Type of the request | High Priority request | ||
---|---|---|---|---|---|
Target | Reaction and process | Incident Energy | Secondary energy or angle | Target uncertainty | Covariance |
96-CM-245 | (n,f) SIG | 0.5 keV-6 MeV | See details | Y | |
Field | Subfield | Created date | Accepted date | Ongoing action | Archived Date |
Fission | Fast Reactors (ADMAB) | 04-APR-08 | 12-SEP-08 | Y |
Send a comment on this request to NEA.
Requester: Prof. Massimo SALVATORES at CADARACHE, FR
Email:
Project (context): NEA WPEC Subgroup 26
Impact:
Accuracy:
Justification document:
Comment from requester:
Additional file attached: SG26-report.html
Review comment:
Entry Status:
Main recent references: Experiments Theory/Evaluation Validation
Design phases of selected reactor and fuel cycle concepts require improved data and methods in order to reduce margins for both economical and safety reasons. A first indicative nuclear data target accuracy assessment was made within WPEC Subgroup 26 (SG-26). The assessment indicated a list of nuclear data priorities for each of the systems considered (ABTR, SFR, EPR, GFR, LFR, ADMAB, VHTR, EPR). These nuclear data priorities should all be addressed to meet target accuracy requirements for the integral parameters characterizing those systems (see the accompanying requests originating from SG-26).
Requested accuracy is required to meet target accuracies for keff, peak power and burnup for the Accelerator-Driven Minor Actinides Burner (ADMAB). Details are provided in the OECD/NEA WPEC Subgroup 26 Final Report: "Uncertainty and Target Accuracy Assessment for Innovative Systems Using Recent Covariance Data Evaluations" (link to WPEC Subgroup 26 Report in PDF format, 6 Mb).
Target accuracies are specified per system and per energy group when they are not met by the BOLNA estimate of the current (initial) uncertainties.
Energy Range Initial versus target uncertainties (%) Initial SFR EFR GFR LFR ADMAB 2.23 - 6.07 MeV 31 7 1.35 - 2.23 MeV 44 14 6 0.498 - 1.35 MeV 49 9 43 16 11 3 183 - 498 keV 37 7 13 7 3 67.4 - 183 keV 48 7 42 11 7 3 24.8 - 67.4 keV 27 9 11 9 3 9.12 - 24.8 keV 14 9 3 2.03 - 9.12 keV 13 4 0.454 - 2.03 keV 13 5
OECD/NEA WPEC Subgroup 26 Final Report: "Uncertainty and Target Accuracy Assessment for Innovative Systems Using Recent Covariance Data Evaluations" (link to WPEC Subgroup 26 Report in PDF format, 6 Mb).
Given the present state of knowledge the above target accuracies are very tight. However, any attempt that significantly contributes to reducing the present accuracy for this quantity is strongly encouraged. Any such attempt will significantly enhance the accuracy with which reactor integral parameters may be estimated and will therefore impact economic and safety margins.
Work in progress (as of SG-C review of May 2018)
Please report any missing information to hprlinfo@oecd-nea.org