3. DESCRIPTION OF PROBLEM OR FUNCTION

PROCIV calculates the protection coefficients against radioactive fallout for collective housing in a residential area. Each house is simulated by a cylindrical tower. The material thickness traversed by the photons is converted to an equivalent layer of air. The masking by neighbouring houses is taken into account.
top ]
4. METHOD OF SOLUTION:
top ]
5. RESTRICTIONS ON THE COMPLEXITY OF THE PROBLEM:
top ]
6. TYPICAL RUNNING TIME

NEA-DB executed all 6 test cases included in  the package (NEA 0695/02) on UNIVAC 1110 in 24 CPU seconds.
top ]
7. UNUSUAL FEATURES OF THE PROGRAM:
top ]
8. RELATED AND AUXILIARY PROGRAMS:
top ]
9. STATUS
Package ID Status date Status
NEA-0695/02 18-OCT-1983 Tested at NEADB
top ]
10. REFERENCES:
NEA-0695/02, included references:
- B. Warme-Janville:
  Code PROCIV for Univac Series 1100 (Version ETCA-CNBC) (July 1982)
top ]
11. MACHINE REQUIREMENTS:  14K words of main storage on UNIVAC 1110.
top ]
12. PROGRAMMING LANGUAGE(S) USED
Package ID Computer language
NEA-0695/02 FORTRAN-V (UNIVAC)
top ]
13. OPERATING SYSTEM UNDER WHICH PROGRAM IS EXECUTED

On UNIVAC 1100 series, FORTRAN-V compilers 11A and T3 are required.
The test cases were executed on UNIVAC 1110 using EXEC-8.
top ]
14. OTHER PROGRAMMING OR OPERATING INFORMATION OR RESTRICTIONS:
top ]
15. NAME AND ESTABLISHMENT OF AUTHOR

B. Warme-Janville
Etablissement Technique Central de l'Armement
Arcueil, France
top ]
16. MATERIAL AVAILABLE
NEA-0695/02
File name File description Records
NEA0695_02.003 PROCIV INFORMATION FILE 56
NEA0695_02.004 PROCIV SOURCE (FORTRAN-4) 1642
NEA0695_02.005 PROCIV JCL 21
NEA0695_02.006 PROCIV DATA VERSION 1, TEST CASE 1 23
NEA0695_02.007 PROCIV DATA VERSION 2, TEST CASE 2 26
NEA0695_02.008 PROCIV DATA VERSION 2, TEST CASE 3 26
NEA0695_02.009 PROCIV DATA VERSION 2, TEST CASE 4 26
NEA0695_02.010 PROCIV DATA VERSION 2, TEST CASE 5 26
NEA0695_02.011 PROCIV DATA VERSION 3, TEST CASE 6 25
NEA0695_02.012 PROCIV COMMON INPUT DATA 20
NEA0695_02.013 PROCIV OUTPUT VERSION 1, CASE 1 241
NEA0695_02.014 PROCIV OUTPUT VERSION 2, CASE 2 225
NEA0695_02.015 PROCIV OUTPUT VERSION 2, CASE 3 225
NEA0695_02.016 PROCIV OUTPUT VERSION 2, CASE 4 265
NEA0695_02.017 PROCIV OUTPUT VERSION 2, CASE 5 265
NEA0695_02.018 PROCIV OUTPUT VERSION 3, CASE 6 728
top ]
17. CATEGORIES
  • G. Radiological Safety, Hazard and Accident Analysis

Keywords: gamma radiation, radiation doses, shielding.