last modified: 17-OCT-1985 | catalog | categories | new | search |

IAEA0898 F5TAB.

F5TAB, ENDF/B-4 FILE 5 Data Conversion to Tabulated Form

top ]
1. NAME OR DESIGNATION OF PROGRAM:  F5TAB.
top ]
2. COMPUTERS
To submit a request, click below on the link of the version you wish to order. Only liaison officers are authorised to submit online requests. Rules for requesters are available here.
Program name Package id Status Status date
F5TAB IAEA0898/02 Tested 17-OCT-1985

Machines used:

Package ID Orig. computer Test computer
IAEA0898/02 IBM 3081 DEC VAX 11/780
top ]
3. DESCRIPTION OF PROGRAM OR FUNCTION

Convert the energy distribution data format (in ENDF/B-IV file 5) from various types of laws to tabulated data points in linear-linear interpolation form.
top ]
4. METHOD OF SOLUTION

1) Convert the function parameters to tabulated data with sufficient    energy points
2) Linearization
3) Add zero-value points at the ends of the energy region
4) Normalization
top ]
5. RESTRICTIONS ON THE COMPLEXITY OF THE PROBLEM

The input data file  must be correctly coded in ENDF/B-IV format especially file 5.
top ]
6. TYPICAL RUNNING TIME

10 seconds on IBM 3081. 4.2 seconds are required for the test problem on VAX. In general, execution times depend on the size of the input data file.
IAEA0898/02
The test case included in this package has been executed by NEA-DB on a VAX-11/780 in 4.2 seconds of CPU time.
top ]
7. UNUSUAL FEATURES OF THE PROGRAM

For ENDF/B-IV file 5 which is already in linear tabulated data form, F5TAB may be useful for re-normalization if some of the data  has been changed.
top ]
8. RELATED AND AUXILIARY PROGRAMS:
top ]
9. STATUS
Package ID Status date Status
IAEA0898/02 17-OCT-1985 Tested at NEADB
top ]
10. REFERENCES:
top ]
11. MACHINE REQUIREMENTS:  Less than 200 K-bytes on VAX.
IAEA0898/02
The peak working set size to run the test case of the package on VAX-11/780 is 333 pages (167K bytes).
top ]
12. PROGRAMMING LANGUAGE(S) USED
Package ID Computer language
IAEA0898/02 FORTRAN-77
top ]
13. OPERATING SYSTEM UNDER WHICH PROGRAM IS EXECUTED:  MVS/OS(IBM),
VMS(VAX-11/780).
top ]
14. OTHER PROGRAMMING OR OPERATING INFORMATION OR RESTRICTIONS

The subroutines 'LINTAB' and "THIN' are standard for general usage on linearization and normarization.
top ]
15. NAME AND ESTABLISHMENT OF AUTHORS

         L.X. Shen
         Chinese Nuclear Data Center
         P.O. Box 275(41)
         Beijing, People's Republic of China
top ]
16. MATERIAL AVAILABLE
IAEA0898/02
File name File description Records
IAEA0898_02.001 information file 49
IAEA0898_02.002 F5TAB source program (FORTRAN) 1080
IAEA0898_02.003 test case jcl & input data 5
IAEA0898_02.004 test case original jcl & input data for IBM 9
IAEA0898_02.005 test case evaluated input data 161
IAEA0898_02.006 test case evaluated output data 185
IAEA0898_02.007 test case printed output 29
top ]
17. CATEGORIES
  • M. Data Management

Keywords: ENDF/B, data processing, evaluated data.