last modified: 08-JUL-2009 | catalog | categories | new | search |

CSNI2101 CABRI-REPNA-2 TEST.

CABRI-REPNa-2 TEST, Assessment of fuel behaviour mechanisms relevant for RIA transients

top ]
1. NAME OR DESIGNATION:  CABRI-REPNa2
top ]
2. COMPUTERS
To submit a request, click below on the link of the version you wish to order. Only liaison officers are authorised to submit online requests. Rules for requesters are available here.

No item found

Machines used:

No item found

top ]
3. DESCRIPTION OF TEST FACILITY

The CABRI REP Na test data provide a very consistent basis for the assessment of fuel behaviour mechanisms relevant for RIA transients. For the CABRI REP Na rods that did not fail,  valuable information on fission gas release and especially on cladding deformation have been generated in the test programme. REP Na cladding strain data have been used as a start point for deriving an admittedly simple RIA failure criterion. This is based on a maximum strain which can be tolerated by the cladding, i.e. failure can occur only when this strain level is exceeded.
- For cladding that still retains ductility, failure at high burn-up (50-60 MWd/kg) is predicted beyond a 1% (permanent) diameter strain.
- For cladding that has been embrittled due to e.g. large corrosion, spalling and hydriding, a zero ductility is assumed, i.e. the failure threshold is at onset (0%) of permanent strain.
  
The conditions under which the ductility decreases from 1% to zero are provisionally set in the paper, taking into account the evidence from the CABRI tests and from ANL laboratory tests. Based on the above, one derives that the lowest failure limit at 60 MWd/kg is ~65-70 cal/g, which applies to heavily corroded/hydrided fuel, i.e. for oxide thickness of ~80 mm and in presence of oxide spalling. For corrosion resistant fuel, i.e. for oxide thickness well below 80 mm and in absence of spalling, the failure threshold at the same burnup is ~100 cal/g.
   
This failure criterion predicts well three of the four failed REP Na tests, but not the REP Na-1 test. For this, the predicted failure threshold is 63 cal/g, whereas the reported experimental value is 30 cal/g. For CABRI unfailed rods, the predicted failure limit is very close to the enthalpy achieved during the test. When used at its higher degree of conservatism (i.e. ductility = 0), the proposed failure threshold predicts reasonably well also the failed NSRR PWR and BWR rods. In general, more data at prototypical conditions are needed in order to arrive to comprehensive, best-estimate failure predictions. The PIE data of unfailed REP Na rods show a remarkable similarity between the trend exhibited by the cladding strain and by the fission gas release. This is briefly discussed in this paper with regard to a possible FGR mechanism (i.e. it is implied that the gas may mostly be released upon cooling, when cladding constraints are reduced). In any case, it appears that FGR as such has little to do with the mechanism of failure when this occurs at low enthalpy.
   
For more detailed information visit
http://www.nea.fr/html/dbprog/cabrirepna/CABRI-REPNa.htm  and
http://www.nea.fr/html/jointproj/cabri.html
top ]
4. DESCRIPTION OF TEST

The REPNa2 CABRI test was performed on June 10th 1997. Its objective was to study the behaviour of a PWR pin, under a RIA type power transient.
   
The tested pin, irradiated in the BR3 reactor (Belgium), had a 26500 MWd/t mean burn-up and a U5 enrichment of 6.85 %.
   
The power transient, irradiated from a 100 kW power plateau, led to an energy release into the pin of 203 cal/g at 200 ms after TOP onset.
   
No pin rupture was detected during the test. However, fuel and clad elongation were measured (approx. 1% of initial fissile length) and the post-test examinations have shown a significant residual clad swelling.
top ]
5. RESTRICTIONS ON THE COMPLEXITY OF THE PROBLEM: EXPERIMENTAL LIMITATIONS OR SHORTCOMINGS
top ]
6. TYPICAL RUNNING TIME: PHENOMENA TESTED
top ]
7. UNUSUAL FEATURES: SPECIAL FEATURES OF EXPERIMENT
top ]
8. RELATED OR AUXILIARY PROGRAMS: COUNTERPART EXPERIMENTS
top ]
9. STATUS

No item found

top ]
10. REFERENCES

A RIA Failure Criterion based on Cladding Strain by C. Vitanza
OECD Halden Reactor Project
Paper presented at the IAEA Technical Committee Meeting on Fuel Behaviour under Transient and LOCA Conditions
top ]
11. TEST DESIGNATION:  REP Na2
top ]
12. PROGRAMMING LANGUAGE(S) USED

No item found

top ]
15. ESTABLISHMENT

Institute de Radioprotection et de Surete Nucleaire
CE Cadarache
13108 St PAUL-LEZ-DURANCE Cedex
top ]
16. MATERIAL AVAILABLE
top ]
17. CATEGORIES

Keywords: fuel behaviour, transients.