To submit a request, click below on the link of the version you wish to order.
Only liaison officers are authorised to submit online requests. Rules for requesters are
available here.
NEPTUN is designed to perform PWR LOCA simulation experiments, which provide the full length emergency cooling heat transfer tests for LOFT. Therefore the NEPTUN heater bundle with 33 electrical heater elements and 4 guide tubes simulates a section of the LOFT nuclear core. The main test loop also contains measuring systems for the carry-over rate and for the steam expelled, and a backpressure control system. A water loop brings the water to the initial reflooding conditions. In addition, auxiliary systems maintain normal operating conditions.
Test 5050 is one of a series of 40 reflood tests performed in NEPTUN. Before the start of the test, the flooding water in its circuit is brought to the following conditions:
pressure = 4.1 bar
velocity = 15.0 cm/sec
subcooling temperature = 78C
single rod power = 2.45 kW
maximal initial cladding temperature = 867C.
- H. Gruetter, F. Stierli, S.N. Aksan, G. Varadi:
Neptun Bundle Reflooding Experiments: Test Facility Description
EIR Bericht Nr. 386, March 1980
- NEPTUN Tape Content
- M. Richner, G.Th. Analytis and S.N. Aksan:
Assessment of RELAP5/MOD2, Cycle 36.02, Using NEPTUN
Reflooding Experimental Data
NUREG/IA-0054 (August 1992)