1 PROGRAM FIZCON VERSION 6.12 Input File Specification------------------------JEFF30N7243_2.ASC Check the Entire File Sum Up Tests will be Performed Fractional Difference Allowed is 0.00200 Deviant Point Check will be Omitted Consecutive Equal Value Check will be Omitted TAPE NOT LABELED 1 CHECK MATERIAL 7243 (NO ERRORS DETECTED IN SECTIONS WITHOUT COMMENTS) -------------------------------------------------------------------------------- FILE 1 SECTION 451 72-HF-180 NAIG+ EVAL-JUL89 HIDA, YOSHIDA AND SHIBATA(JAERI) DIST-APR02 ----JEFF-30 MATERIAL 7243 -----INCIDENT NEUTRON DATA ------ENDF-6 FORMAT -------------------------------------------------------------------------------- FILE 2 SECTION 151 -------------------------------------------------------------------------------- FILE 3 SECTION 1 SECTION 2 SECTION 4 SECTION 16 SECTION 17 SECTION 51 SECTION 52 SECTION 53 SECTION 54 SECTION 55 SECTION 56 SECTION 57 SECTION 58 SECTION 59 SECTION 60 SECTION 61 SECTION 91 SECTION 102 SECTION 103 SECTION 107 SECTION 251 SUMUP TEST RESULTS MT= 103 PARTIALS ARE NOT PRESENT -- NO TEST MT= 107 PARTIALS ARE NOT PRESENT -- NO TEST -------------------------------------------------------------------------------- FILE 4 SECTION 2 SECTION 16 SECTION 17 SECTION 51 SECTION 52 SECTION 53 SECTION 54 SECTION 55 SECTION 56 SECTION 57 SECTION 58 SECTION 59 SECTION 60 SECTION 61 SECTION 91 MISSING SECTIONS NO REQUIRED SECTIONS MISSING -------------------------------------------------------------------------------- FILE 5 SECTION 16 FOR LF=1 EPMAX FOUND TO BE 7.50000E+05 SHOULD BE 4.14200E+04 FOR LF=1 EPMAX FOUND TO BE 7.50000E+05 SHOULD BE 6.12320E+05 FOR LF=1 EPMAX FOUND TO BE 1.75000E+06 SHOULD BE 1.61232E+06 FOR LF=1 EPMAX FOUND TO BE 2.75000E+06 SHOULD BE 2.61232E+06 FOR LF=1 EPMAX FOUND TO BE 3.75000E+06 SHOULD BE 3.61232E+06 FOR LF=1 EPMAX FOUND TO BE 4.75000E+06 SHOULD BE 4.61232E+06 FOR LF=1 EPMAX FOUND TO BE 5.75000E+06 SHOULD BE 5.61232E+06 FOR LF=1 EPMAX FOUND TO BE 6.75000E+06 SHOULD BE 6.61232E+06 FOR LF=1 EPMAX FOUND TO BE 7.75000E+06 SHOULD BE 7.61232E+06 FOR LF=1 EPMAX FOUND TO BE 8.75000E+06 SHOULD BE 8.61232E+06 FOR LF=1 EPMAX FOUND TO BE 9.75000E+06 SHOULD BE 9.61232E+06 FOR LF=1 EPMAX FOUND TO BE 1.07500E+07 SHOULD BE 1.06123E+07 FOR LF=1 EPMAX FOUND TO BE 1.17500E+07 SHOULD BE 1.16123E+07 FOR LF=1 EPMAX FOUND TO BE 1.27500E+07 SHOULD BE 1.26123E+07 SECTION 17 FOR LF=1 EPMAX FOUND TO BE 7.50000E+05 SHOULD BE 7.56000E+04 FOR LF=1 EPMAX FOUND TO BE 7.50000E+05 SHOULD BE 5.12600E+05 FOR LF=1 EPMAX FOUND TO BE 1.75000E+06 SHOULD BE 1.51260E+06 FOR LF=1 EPMAX FOUND TO BE 2.75000E+06 SHOULD BE 2.51260E+06 FOR LF=1 EPMAX FOUND TO BE 3.75000E+06 SHOULD BE 3.51260E+06 FOR LF=1 EPMAX FOUND TO BE 4.75000E+06 SHOULD BE 4.51260E+06 FOR LF=1 EPMAX FOUND TO BE 5.75000E+06 SHOULD BE 5.51260E+06 FOR LF=1 EPMAX FOUND TO BE 6.75000E+06 SHOULD BE 6.51260E+06 SECTION 91 MISSING SECTIONS NO REQUIRED SECTIONS MISSING -------------------------------------------------------------------------------- FILE 12 SECTION 16 SECTION 17 SECTION 51 SECTION 52 SECTION 53 SECTION 54 SECTION 55 SECTION 56 SECTION 57 SECTION 58 SECTION 59 SECTION 60 SECTION 61 SECTION 91 SECTION 102 SECTION 103 SECTION 107 -------------------------------------------------------------------------------- FILE 14 SECTION 16 SECTION 17 SECTION 51 SECTION 52 SECTION 53 SECTION 54 SECTION 55 SECTION 56 SECTION 57 SECTION 58 SECTION 59 SECTION 60 SECTION 61 SECTION 91 SECTION 102 SECTION 103 SECTION 107 MISSING SECTIONS NO REQUIRED SECTIONS MISSING -------------------------------------------------------------------------------- FILE 15 SECTION 16 SECTION 17 SECTION 91 SECTION 102 SECTION 103 SECTION 107 MISSING SECTIONS NO REQUIRED SECTIONS MISSING